Click on the heater model for additional information and specificaions.
Note: Specifications are subject to change without notice or obligation.
|
Specifications for Heatec Hot Oil Heaters
|
| Model |
Output
Btu/hour |
Fuel usage |
Recirculation
Pump |
Expansion
Tank |
| No.2 gph |
Gas cfh |
Hp |
gpm |
gallons |
|
SINGLE CIRCUIT HEATERS
|
| HCS-70 |
700,000 |
6 |
910 |
10 |
100 |
100 |
| HCS-100 |
1,200,000 |
11 |
1,560 |
10 |
100 |
175 |
| HCS-175 |
2,000,000 |
18 |
2,600 |
15 |
150 |
280 |
| HCS-250 |
3,000,000 |
27 |
3,900 |
15 |
150 |
280 |
| HCS-400 |
4,000,000 |
36 |
5,200 |
15 |
250 |
400 |
| MULTI-CIRCUIT HEATERS |
| HC-120 |
1,200,000 |
11 |
1,560 |
10 |
100 |
175 |
| HC-200 |
2,000,000 |
18 |
2,600 |
15 |
150 |
280 |
| HC-300 |
3,000,000 |
27 |
3,900 |
15 |
150 |
280 |
| HC-400 |
4,000,000 |
36 |
5,200 |
15 |
250 |
400 |
| The amount of fuel used is for one hour of operation at maximum output. A properly sized heater normally runs for intermittent periods at lower outputs. No. 2 fuel usage is based on 132,000 Btu per gallon, its LHV (low heating value). Natural gas usage is based on 905 Btu per cubic foot, its LHV. |
|