Vertical asphalt storage tanks
Thermo-Guard® vertical asphalt tanks
Asphalt products > Asphalt tanks > Vertical asphalt tanks > Fast heating

Asphalt tanker unload asphalt into two Heatec 30,000 gallon AC tanks

Fast heating
Thermo-Guard asphalt tanks heat faster than competitive tanks. That's because our tanks have two to three times the amount of heating surface normally provided on other tanks.

We put two layers of highly-efficient finned heating coils in the bottom. When in use hot oil flows through the coils to heat the material in the tank.

The time it takes to raise the temperature of asphalt is related to the amount of heating surface. For example, suppose you get a tanker load (6,000 gallons) of asphalt that needs to have its temeprature raised only 10 degrees, from 290 to 300°F. Our tank can do the job in only 20 minutes.

Tanks with less heating surface will take longer. Long waits for AC to reach temperature can disrupt your work flow. The table below compares times for competitor tanks and different temperature increases.

Time to raise the temperature of a 6,000 gallon load of asphalt
Temperature
Increase
Heatec
20,000 gallon vertical tank
1,100 sq ft heating surface
Competitor A
20,000 gallon vertical tank
292 sq ft heating surface
Competitor B
20,000 gallon vertical tank
575 sq ft heating surface
290°F to 300°F 20 minutes 56 minutes 32 minutes
280°F to 300°F 38 minutes 107 minutes 60 minutes
340°F to 350° F
(PMAC)
39 minutes 114 minutes 62 minutes
330°F to 350° F
(PMAC)
70 minutes 207 minutes 113 minutes
Based on a hot oil temperature of 400°F with a flow rate of 50 gpm





Home | Profile | Products - Asphalt | Products - Industrial | Products - Concrete
Literature | Tec-Notes | Parts | Service | Employment | Contacts

Please contact Heatec, Inc. at
Phone (423) 821-5200 | Toll-Free (800) 235-5200 | Fax: (423) 821-7673
5200 Wilson Road | P.O. Box 72760 | Chattanooga, Tennessee 37410

©2007 Astec Industries, Inc. All Rights Reserved.
Legal Notice | Privacy Policy | Webmaster