Pages: 1, 2, 3, 4, 5, 6, 7, 8, 9


Figure 4. Barksdale pressure differential switch CDPD2H-A80SS


Figure 5. Sight gauge.


Figure 6. Drain valve in strainer flange.
Wear chemical and heat resistant gloves as protection from hot oil.


Figure 7. Controls on LH side of burner.

Operating mode

Valves on heater thermal fluid piping

Valve No. 1

Valve No. 2

Valve No. 3

Valve No. 4

Run

Open

Closed

Open

Open

Purge

Closed

Open

Open

Open

Clean Strainer

Closed

Closed

Closed

Closed

Figure 8. Valve settings for operating modes.

Modulating
Controller set point

High Temp. Controller set point

HCS Heater

HC Heater

320 degrees F

370 degrees F

400 degrees F

350 degrees F

400 degrees F

430 degrees F

370 degrees F

420 degrees F

450 degrees F

 

(Normally 50 degrees F higer than set point on Modulating Controller

(Normally 80 degrees F higer than set point on Modulating Controller)

Figure 9. Suggested set points for High Media Temp. Controller.


Figure 10. Main disconnect circuit
breaker.


Figure 11. Control transformer.